Azzera filtri
Azzera filtri

PROBLEM SIMULINK CONNECTING BLOCKS

18 visualizzazioni (ultimi 30 giorni)
Andreas
Andreas il 30 Mar 2012
Commentato: Tejaswini Rao il 25 Giu 2017
I try to connect a ground to the Controlled PWM Voltage block in the -ref port but it cannot be done as, some software or gui problem exists. The same problem appeared with other ports of this block. IS IT SOFTWARE BUG or AM I trying to do something "illegal" given the properties of the blocks I am trying to connect???
I use Simulink 7.6(R2010b)
Thanks

Risposta accettata

Kaustubha Govind
Kaustubha Govind il 30 Mar 2012
You cannot connect Simulink components to SimScape (SimElectronics) components. Try using the Electrical Reference block instead of the Ground block from the Simulink library.
  2 Commenti
Andreas
Andreas il 30 Mar 2012
Ok thank you Kaustubha. I did that and i did make it to connect the "ground". I first tried Simulink PS converter for that but it did not work so ELECRICAL REFERENCE block seems to do the job correctly.
Tejaswini Rao
Tejaswini Rao il 25 Giu 2017
Thank you. I was stuck for many days. Your answer helped me.