simulink add_block fails for 'built-in/Transfer Fcn' is it because of the white space?

Risposte (1)

Swarooph
Swarooph il 28 Giu 2017
Using block names like 'Transfer Fcn' works only if you use the full block path as follows:
add_block('simulink/Continuous/Transfer Fcn', 'untitled/Transfer Fcn')
Otherwise, you can use 'built-in/blocktype' as a source block path name for Simulink built-in blocks, where blocktype is the built-in block type (that is, the value of its BlockType parameter (see Common Block Properties). However, using 'built-in/blocktype' causes some default parameter values of some blocks to be different from the defaults that you get if you added those blocks interactively using Simulink.
add_block('built-in/TransferFcn', 'untitled/Transfer Fcn1')
More on the documentation here.