Simscape Full-Bridge Error
    5 visualizzazioni (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
I'm using a PWM generator as the gate signal for the full-bridge block. I want to simulate a single phase full-bridge inverter. I'm getting an error that says since the pwm generator has an 8 pulse output and the converter block is only 4 pulses, it won't work.
Can someone tell me what I'm doing wrong and how to simulate a single-phase full-bridge inverter with this block? (The example is no help)
I've attached a few illustrative pics. Thanks!
<<

>>

0 Commenti
Risposte (1)
  Joel Van Sickel
    
 il 2 Set 2020
        Hello Ryan, 
you are using a PWM generator designed for a 3 level inverter.  This is a 2 level full-bridge.  Please use the 2 level PWM generator, and select the appropriate topology (it will default to a 6 device inverter, but can be set to work for a full-bridge).
Regards,
Joel
0 Commenti
Vedere anche