Noise Generated using awgn and randn do not match!!!
Mostra commenti meno recenti
I am generating noise in two different cases with the same SNR once using awgn command which is a built in command and second time using randn function with the correct scaling however I am getting different noise power in each case.
Following is the script to generate noise using different techniques. Can anyone help me why I am not getting the correct result?
Method 1
A=[1-1i 1+5i 5-4i 3+2i 6-1i 1-3i 2 1+1i -1-0.5i];
Esym=sum(abs(A).^2)/length(A);
SNR=0;
snr=10^((SNR)/10);
Noise=sqrt(Esym/(2*snr))*(randn(1,length(A))+1i*randn(1,length(A)));
A_noisy=A+Noise;
sum(abs(C).^2)/length(C) sum(abs(Noise).^2)/length(Noise) Method 2
B=awgn(A,SNR,'measured');
C=B-A;
The result is as follow:
sum(abs(C).^2)/length(C)
sum(abs(Noise).^2)/length(Noise)
>> noise_testing
ans =
19.4895
ans =
7.9002
As you can see the result is so much different. Can anyone help me to figure out the problem.
Thanks
Risposta accettata
Più risposte (1)
Marco
il 3 Ott 2017
0 voti
Hello, you could find a possible answer at this link: https://it.mathworks.com/matlabcentral/answers/40772-snr-in-awgn
BR Marco