collect 400 samples from a LFM (5MHz bandwidth) signal modulated on 18GHz

3 visualizzazioni (ultimi 30 giorni)
f_sweep = 5e6; fs = f_sweep * 4.121; sLFM = phasedLinearFMWaveform('SampleRate',fs,'SweepBandWidth',f_sweep,'PulseWidth',1e-3); lfmwav = setp(sLFM); collector = phase.WidebandCollector('Sensor',URA, 'SampleRate',fs,'CarrierFrequency',18e9); S1=awgn(lfmwav,-10,'measured'); Y=collector(S1(1:400),[20;30]);
  1 Commento
Chen
Chen il 23 Gen 2018
the problem is once I get 400 samples, I did FFT on these sample, the center frequency is not at 18GHz.

Accedi per commentare.

Risposta accettata

Honglei Chen
Honglei Chen il 23 Gen 2018
Your sampling rate is set at fs, which is about 20 MHz, this means your Nyquist is about 10 MHz, regardless what your carrier is, i.e., your signal is aliased. If you want to see 18 GHz at the center, you will have to sample at 36 GHz, this is obviously very expensive. On the other hand, the first step in receiver is normally mix it down so the carrier frequency is really used for transmission, and does not affect the signal processing much (except we need to compensate for RF distortions). This is why we often simply simulate at base band because it captures all the band that interests us.
HTH

Più risposte (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by