Simulink turn off data logging
90 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hello ! I do have the following problem: I have a very big simuling model, with a lot of subsystems. In this model a lot of signal have already logged. I'm making a test environment to run this model, and I have to test the result of the simulation. I have to log only a few data, but in the model there are approximately 150 logged signal (and it's made the simulation much slower). So for that, in my test environment I'd like to unlog all of the signal, and turn on only witch are necessary for me.
0 Commenti
Risposta accettata
TAB
il 28 Mag 2018
Modificato: TAB
il 28 Mag 2018
Disable all logging at once
% Find all ports with data logging enabled
pH = find_system('YourModelName', 'FindAll', 'on', 'Type', 'Port', 'DataLogging', 'on');
% Disable all logging
for x=1:length(pH)
set_param(pH(x), 'DataLogging', 'off');
end
2 Commenti
Sina Sharifi
il 2 Lug 2020
Modificato: Sina Sharifi
il 2 Lug 2020
Hi
I had a similar problem.
These lines solved it. Thank you.
Sina
Più risposte (2)
Paul Smith
il 31 Gen 2019
I had a similar issue, I ended up modifying to this though:-
pH = find_system('Your Model name','LookUnderMasks','all','FindAll', 'on', 'DataLogging', 'on');
'Type', 'Port'
Having type and port in the search misses other potentially logable terms.
0 Commenti
Zhu
il 26 Lug 2019
Turn this model into .mdl format
Open model in text
Find all "datalogging on", set it to off
Done!
3 Commenti
Herman Wong
il 7 Mar 2024
Modificato: Herman Wong
il 7 Mar 2024
set_param(bdroot, 'InstrumentedSignals', []) --- awesome! Thanks Jun Yang!