Simulink turn off data logging
Mostra commenti meno recenti
Hello ! I do have the following problem: I have a very big simuling model, with a lot of subsystems. In this model a lot of signal have already logged. I'm making a test environment to run this model, and I have to test the result of the simulation. I have to log only a few data, but in the model there are approximately 150 logged signal (and it's made the simulation much slower). So for that, in my test environment I'd like to unlog all of the signal, and turn on only witch are necessary for me.
Risposta accettata
Più risposte (2)
Paul Smith
il 31 Gen 2019
4 voti
I had a similar issue, I ended up modifying to this though:-
pH = find_system('Your Model name','LookUnderMasks','all','FindAll', 'on', 'DataLogging', 'on');
'Type', 'Port'
Having type and port in the search misses other potentially logable terms.
Zhu
il 26 Lug 2019
0 voti
Turn this model into .mdl format
Open model in text
Find all "datalogging on", set it to off
Done!
3 Commenti
Jun Yang
il 20 Nov 2023
this command works in a better way!
set_param(bdroot, 'InstrumentedSignals', [])
Herman Wong
il 7 Mar 2024
Modificato: Herman Wong
il 7 Mar 2024
set_param(bdroot, 'InstrumentedSignals', []) --- awesome! Thanks Jun Yang!
Jinggang
il 9 Lug 2024
Thank u Jun Tang, it works!