I have created a Simulink model with only a constant value (see screenshot).
Then I execute it by running the following script:
clear
set_param DummyTest FixedStep 1
sim DummyTest
disp(y.Time)
Turns out the step size of the simulation is 0.2 s, not 1 second. What do I do wrong?

Risposta accettata

Fangjun Jiang
Fangjun Jiang il 29 Mag 2018
The setting of this parameter is dependent. It won't take effect until other settings are in place. You can check the solver type by the following. It must have been been 'Variable-step'.
get_param('DummyTest','SolverType')
After setting the following, you 1 second fixed step will take effect
set_param('DummyTest','SolverType','Fixed-step');

Più risposte (1)

ES
ES il 29 Mag 2018
You have set the solver?
set_param('Solver', 'FixedStepDiscrete');