Simscape - how to set outputs from measurement blocks as complex values
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hello,
Attached is my simple Simulink (Simscape) model. My question would be: is it possible to get output values from the "Three-Phase V-I Measurement" block as complex numbers? I have set up all the parameters as I thought they should be, but as you can see I still get real values for that block output (Vabc). Am I doing something wrong?
Thanks
0 Commenti
Risposte (1)
Joel Van Sickel
il 2 Set 2020
Hello Vanja,
these models do not output complex values, they output the instantaneous actual value at a given time. All three phase's instintaneous values are available, so youc an calculate the complex representation, but the signals should still be maintained as real-scalars inside the simulink model if you want to manipulate them. You can use blocks like this if you want to use complex numbers in simulink: https://www.mathworks.com/help/simulink/slref/realimagtocomplex.html,
Regards,
Joel
0 Commenti
Vedere anche
Categorie
Scopri di più su Electrical Sensors in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!