Simulink mask display programmatically, how to make line shift?

6 visualizzazioni (ultimi 30 giorni)
I use this command to set up mask display programmatically:
set_param( gcbh,'MaskDisplay', ['port_label(''input'', 1, ''in1''); port_label(''output'', 1, ''out1'');'] );
In the mask editor it afterwards appears in one line as:
port_label('input', 1, 'in1'); port_label('output', 1, 'out1');
which is a bit annoying when the block has many ports.
How can I make it appear in multiple lines, like:
port_label('input', 1, 'in1')
port_label('output', 1, 'out1')

Risposta accettata

Fangjun Jiang
Fangjun Jiang il 19 Set 2018
use char(10),
set_param( gcbh,'MaskDisplay', ['port_label(''input'', 1, ''in1'');',char(10),'port_label(''output'', 1, ''out1'');'] );

Più risposte (1)

Flemming
Flemming il 20 Set 2018
Thanks, it works.

Categorie