Question about how to run TX and RX calibration example model on zedboard with zynq
Mostra commenti meno recenti
I am doing an experiment: I combined the following two examples:
Transmitter example: https://ww2.mathworks.cn/help/supportpkg/xilinxzynqbasedradio/examples/frequency-offset-calibration-transmitter-using-analog-devices-ad9361-ad9364.html
Receiver example: https://ww2.mathworks.cn/help/supportpkg/xilinxzynqbasedradio/examples/frequency-offset-calibration-receiver-using-analog-devices-ad9361-ad9364.html
The combined model is shown in the image:

I have the boards: AD-FMCOMMS4-EBZ(which is AD9364) evaluation board) and Zedboard with Xilinx Zynq. when I run the model, the signal plotted in time scope is discontinuous sin wave but not continuous sin wave. | | Is the discontinuous sin wave plotted in time scope correct?||


Risposta accettata
Più risposte (2)
Ardeal Liang
il 18 Ott 2018
0 voti
Ardeal Liang
il 22 Ott 2018
Modificato: Ardeal Liang
il 22 Ott 2018
0 voti
1 Commento
Paul
il 23 Ott 2018
There are some bottlenecks involved in running a receiver and a transmitter in Normal mode in Simulink at the same time on the same device. It requires for the data to go from the chip to the host with too high rates to ensure continuous streaming. This is not a supported use case.
That is why you should consider using the `transmitRepeat` functionality as highlighted above. It will let the transmitter transmit without being actively fed by the host, it will transmit a given waveform repeatedly.
As for your question on the loopback cable, please refer to my answer here to your similar question.