Add dead time in Simulink
211 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Jiaxiu Dong
il 14 Dic 2018
Commentato: Lazuardi Agung
il 17 Dic 2022
Hi, I am trying to control an H bridge cell. So in order to avoid two swithes turn ON at the same time, I need to add the dead time. I would expect a similar waveform as below. Does anyone konw how to achieve this in Simulink? Thank you so much!
0 Commenti
Risposta accettata
Rick Hyde
il 12 Nov 2021
We now have the Gate Driver and Half-Bridge Drive blocks in Simscape™ Electrical™ which allow you to specify dead-time/blanking time in a numerically efficient way. Please see the screenshot below. Hope you find this solution useful.
Rick
2 Commenti
Nueraimaiti Aimaier
il 10 Ott 2022
Hi,
This is helpful, thanks. However, what kind of ports (or devices) should be connect to the output of Driver? I used Simulink-PS converter for the input, it can be connected. But, at the output, I used PS-Simulink converter and it cannot connected to Simulink signal MOSFET.
Rick Hyde
il 17 Ott 2022
The output pins of the driver block should be directly connected to Simscape electrical ports on semiconductor device models in the Simscape Electrical library.
Più risposte (3)
Yonghui Xu
il 28 Mar 2019
Add following blocks to your switching signal path and you can set the deadtime by setting the time delay of the transport dealy block.
2 Commenti
Mark Sherstan
il 14 Dic 2018
try: Transport Delay
5 Commenti
Zoe Blatsi
il 4 Giu 2020
Hello,
I tried this for my discrete time PWM model:
and it seems to be working alright:
you could even configure a variable delay in the "delay" block settings.
I hope that helps.
Zoe
Lazuardi Agung
il 17 Dic 2022
thanks, for solving my problem. by just adding transport delay block we can easyly add dead time control
0 Commenti