PUSCH Throughput Conformance Test got throughput 0 with ue.RC = 'A4-3'

In this example, changed the FRC from A3-2 to A4-3, then Run this script, got 0 throughput for all SNR values,not sure anything others needed to change or not?
UE Configuration
User Equipment (UE) settings are specified in a structure form.
ue.RC = 'A3-2'; % FRC number
BRs,
Scott

 Risposta accettata

Più risposte (2)

Graham Freeland
Graham Freeland il 5 Feb 2019
Modificato: Graham Freeland il 6 Feb 2019
Hi,
You'll have to move the SNR range of the simulation up since the code rate is now a lot higher, going from 1/3 (A3-2) to 3/4 (A4-3). You'll also need to increase the length of the simulation to get reliable results (the simulation example code is set to a short run to make it practical in the first instance).

1 Commento

Thanks for the answer, do we have recommended range of simulation length for different code rate?

Accedi per commentare.

The simulation length will generally depend on the channel doppler. A4-3 is used in reference tests using EPA5 or EVA70 channels. The standard specifes very long simulations for RAN4 tests but 1000-5000 subframes may be sufficient for reasonable convergence.
Graham

Categorie

Prodotti

Release

R2018b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by