How to model an interphase transformer using mutual inductance blocks (IPT)

16 visualizzazioni (ultimi 30 giorni)

Risposta accettata

MathWorks Support Team
MathWorks Support Team il 25 Apr 2019
If you desire to model an interphase transformer such as the 2-interphase Transformer detailed in the documentation attached,"modeling and analysis of multi-IPT.pdf", you actually need two mutual inductance blocks. The current enters at each mutual inductance block's respective input marked by 1. The inputs marked by 2 are connected to the output of the opposite mutual inductance block's second output. Finally, the first output of each mutual inductance block combine which signify the output path of the current. This can be seen in the solution model attached, "InterPhaseTransformer_16a.slx".

Più risposte (0)

Categorie

Scopri di più su Thermal Analysis in Help Center e File Exchange

Prodotti


Release

R2016a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by