Hey,
I'm using the session based commands to control a NI DAQ device with Matlab 2011b 64-bit. Amongst other things I need to trigger some signal generators with a 5V rising edge. Heretofore I used the legacy interface's digital I/Os which can't be used anymore in the 64-bit version.
Which options do I have, if I don't want to go back to Matlab 32-bit?
Best regards Tobi
0 Commenti
Risposta accettata
Manisha
il 24 Ago 2012
Modificato: Manisha
il 24 Ago 2012
Hi Tobi,
Support for non-clocked DIO has been added to the Session-based interface in MATLAB R2012b pre-release. If you have a valid license, you can install the prerelease here.
Thanks,
Manisha
2 Commenti
Hugo Malagon
il 18 Set 2012
Hi Manisha and Tobi,
So, are you suggesting that the entire MATLAB R2011b 64-bit does not support digital ports of a NI DAQ ???... I mean, I am having the same problem... I want to use my Digital I/O ports, but I cannot on the session - based interface of the MATLAB R2011b 64-bit.
Is it impossible?? Do I have to either go back to a version with legacy interface or update or R2012b??
regards,
Hugo.