ERROR: floating constant is out of range
10 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I have created a algorithm in Simulink. I tried to implement this model to TI TMS320F28379D LAUNCHXL board embedded target. When I try to build the model, I receive the following error messages.
This is one of the code segments that caused error
1 Commento
Walter Roberson
il 29 Ott 2022
Modificato: Walter Roberson
il 29 Ott 2022
I wonder where that constant comes from; too bad it isn't documented. It happens to be 0x1cc0000000000000 but that does not tell me anything about what it represents.
Ah... with further checking I see that it is
format long g
eps(sqrt(realmin))
and that suggests its replacement value should be
eps(sqrt(realmin('single')))
Risposta accettata
Mike Hosea
il 7 Mag 2019
That number is well within the range of IEEE double precision floating point numbers, but the TI TMS320F28379D has native 32bit IEEE single precision floating point. I'm not sure what the C compiler for it does with double precision data, but based on what you have shown, it doesn't seem to support IEEE double precision floating point, even in emulation. Try using single precision.
3 Commenti
Dajr Alfred
il 15 Mag 2023
The easiest way to accomplish this with simulink is to use the Single Point Converter in the Apps tab
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Simulink Coder in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!