Please help me to sove this problem, thank you so much!

27 visualizzazioni (ultimi 30 giorni)
Error in 'bingwangnibia1/Subsystem/vo': Initialization commands cannot be evaluated.
Caused by:
  • PSB option menu block block (mask) does not have a parameter named 'NonlinearTolerance'
  3 Commenti
BAMMIDI RAVITEJA
BAMMIDI RAVITEJA il 21 Giu 2022
Delete Powergui block of new version and Replace with the block from your Installed Simulink library.It helped me.
Ali Hussein Numan
Ali Hussein Numan il 6 Lug 2024
Modificato: Ali Hussein Numan il 6 Lug 2024
Yes replace the powergui block from your Installed Simulink library with the old one

Accedi per commentare.

Risposta accettata

Andrew
Andrew il 25 Giu 2019
This looks like an issue with your specific model saved in a previous release being opened in a newer release. Reviewing our issue tracking database, I believe this issue has been fixed in MathWorks release R2019a. Please could you try opening your model in that version, and if it doesn't work please could you directly contact MathWorks support to provide them with your model.

Più risposte (1)

Yuan Ren
Yuan Ren il 11 Set 2019
Drag a "powergui" from the library might help.
  2 Commenti
Xuanqi Zhao
Xuanqi Zhao il 2 Nov 2019
Yeah, I solved the same question in this way, thanks a lot.
Anton Shavin
Anton Shavin il 21 Ago 2020
Same for me. Was one block from older Simulink version opened in the newer one