Thermal network transformation: Foster fourth order to Cauer first order?

9 visualizzazioni (ultimi 30 giorni)
Hello, in the symscape power systems example "Loss Calculation in a Three-Phase 3-Level Inverter" there's a block of a half-bridge IGBT with loss calculation. I wanted to know how you calculated the junction to case thermal resistance and the junction thermal capacitance for this block, since the manufacturer’s datasheet only gives the R and C parameters of a fourth order Foster network, and from what I see in the example the junction to case thermal resistance and the junction thermal capacitance correspond to a first order Cauer representation.

Risposta accettata

Carlos Rueda
Carlos Rueda il 19 Dic 2019
Spostato: Sabin il 23 Dic 2022
A method to find the equivalent Cauer network from the fourth-order Foster network is shown in Appendix A of book "Transient Electro-Thermal Modeling of Bipolar Power Semiconductor Devices" by Gachovska et al.

Più risposte (1)

Joel Van Sickel
Joel Van Sickel il 24 Ago 2020
Moving Carlos Rueda's answer down here to clean up which questions are flagged as unanswered.
Carlos Rueda on 19 Dec 2019
A method to find the equivalent Cauer network from the fourth-order Foster network is shown in Appendix A of book "Transient Electro-Thermal Modeling of Bipolar Power Semiconductor Devices" by Gachovska et al.