Why are my simulink initial conditions sometimes not met, despite high priority?

3 visualizzazioni (ultimi 30 giorni)
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.tf.PNG
  1 Commento
Hari Krishna Ravuri
Hari Krishna Ravuri il 31 Lug 2019
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.

Accedi per commentare.

Risposte (1)

Martin
Martin il 4 Ott 2023
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.