Azzera filtri
Azzera filtri

How to disable termination character while setting up serial object?

12 visualizzazioni (ultimi 30 giorni)
I have to establish with a serial communication device that uses the following properties:
baud = 115200, parity = none, timeout = 500ms, termination char = None, stopbits = 1.
The matlab documentation provides all property values except that on how to disable the termination character.
Any ideas?

Risposta accettata

Guillaume
Guillaume il 26 Lug 2019
The matlab documentation provides all property values except that on how to disable the termination character.
How about the 'Terminator' property?
  2 Commenti
Abhilash Sukumari
Abhilash Sukumari il 29 Lug 2019
This is to be used only when you want to specify a termination character. What if you are dealing with a fixed message serial protocol that doesn't have a termination character ?
Guillaume
Guillaume il 29 Lug 2019
s.Terminator = '';
%or
s.Terminator = [];
seems to work fine in that it does not throw an error even if you write to the serial port. I don't have a device connected to my serial port to check that it actually does what you want.

Accedi per commentare.