PMSM (Single-Phase) missing the cogging torque

16 visualizzazioni (ultimi 30 giorni)
Hi, I'd like to use this model but it miss the cogging torque, wich is very important in this single-phase diapason motor.
Without the cogging effect, the model is too far from the real, and it's not useful.
Is there any suggestion to apply a cogging torque?
Is it possible to apply a sinusoidal torque related to the angular rotor position?
How should I model a cogging torque to bring my rotor back to the standstill position due the asymmetric air gap?
Thankyou

Risposta accettata

Federico Manfrin
Federico Manfrin il 17 Set 2019
Thing went on and I found something to solve this question, and I just want to share with you my experience: PMSM (single phase) was too simple for my project, a better solution is FEM-Parametrized Rotary Actuator.
Whith this block, you can provide a flux mapping table .. phy = f(i;theta) (flux function of current and rotor position). I get the tables using FEMM and a matlab scrpit, but I think there could be some example tables.
Whith this solution .. I get the cogging torque, and for example, if I set a random initial position, the rotor, in the simulation, move to the minimum reluctance position without any current at the input.

Più risposte (0)

Tag

Prodotti


Release

R2019a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by