Simulation of PMSM Current Control using FCS-MPC
13 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hi everyone
I'm trying to control a pmsm current using finite control set MPC, when I'm using PMSM model in simscape everything is fine and currents can track id and iq (currents in dq reference frame) but the problem is PMSM model is based on modified park transform (90 degree behind phase a) and our calculations are based on the original park.
when I change the PMSM model park transform to original park, the results change and FCS-MPC does not work properly.
does anybody have this problem?
Thank you in advance
1 Commento
ty
il 14 Ago 2025
can you send the simulation and the script please????appreciate! 1850478638@qq.com.
Risposte (1)
Shang-Chuan Lee
il 10 Giu 2022
Hi Hossein,
It sounds to me the rotor angle definition of PMSM isn't aligned with your control algortihm where the Park/Clarke Transform on the dq-axis. I would suggest first check the current signals to the "Park Transform" block as well as the "Clarke Transform" block from the current measurement signals.
Best,
Shang-Chuan
0 Commenti
Vedere anche
Categorie
Scopri di più su Switches and Breakers in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!