Azzera filtri
Azzera filtri

How do I verify BLDC motor fidelity?

2 visualizzazioni (ultimi 30 giorni)
William Mercier
William Mercier il 30 Mar 2020
Risposto: Joel Van Sickel il 1 Set 2020
I input the parameters of the 3 phase BLDC motor block (https://www.mathworks.com/help/releases/R2019b/physmod/sps/ref/bldc.html) from a specific datasheet, and supplied it with the nominal voltage from the datasheet with 100% duty cycle (using DC voltage source and inverter block) with no load but the simulation's resultant motor speed is less than half of the specified no load speed in the datasheet. Does anyone have an idea about how to fix this problem please?
  1 Commento
Rahul Singh
Rahul Singh il 31 Mar 2020
Hi William,
Kindly contact MathWorks Technical Support for your query and they can assist you in resolving the issue.
Regards,
Rahul

Accedi per commentare.

Risposte (1)

Joel Van Sickel
Joel Van Sickel il 1 Set 2020
Hello William,
can you share the model in which you apply a duty cycle of 100%? Since a closed loop control algorithm is required to drive a BLDC at max speed, it is possible the closed loop test simulation is incorrect while the parameters are correct. It would also be good to double check wether poles or pole pairs were used in the parameterization as that is an easy place to end up with a factor of 2 error.
Regards,
Joel

Community

Più risposte nel  Power Electronics Control

Categorie

Scopri di più su Simscape Electrical in Help Center e File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by