PID BLOCK IN SIMULINK
11 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Uzair Akhtar
il 13 Apr 2020
Commentato: Ameer Hamza
il 14 Apr 2020
I have worked out that my PID controller is
Gc = 4.2(1 + 1/1.57s + 0.39s)
I want to put this into a block on simulink but the PID controller block in simulink is in a weird form. Does anyone know how to get around this. Thanks.
0 Commenti
Risposta accettata
Ameer Hamza
il 13 Apr 2020
In the Simulink PID block, In the form field, change the form from parallel to ideal and set the value of filter coefficient N to be quite high (say 200). Then parameters P, I, and D can be used from your current transfer function.
2 Commenti
Ameer Hamza
il 14 Apr 2020
PID block uses a low-pass filter for D term. The value of N controls the stop-band of the low-pass filter. Higher the value of N, higher is the stop-band frequency. For the low-value of N, the PID block will smooth the derivative of your system. If you have a high value of N, the filter will have no significant effect.
Più risposte (0)
Vedere anche
Categorie
Scopri di più su PID Controller Tuning in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!