PID BLOCK IN SIMULINK

11 visualizzazioni (ultimi 30 giorni)
Uzair Akhtar
Uzair Akhtar il 13 Apr 2020
Commentato: Ameer Hamza il 14 Apr 2020
I have worked out that my PID controller is
Gc = 4.2(1 + 1/1.57s + 0.39s)
I want to put this into a block on simulink but the PID controller block in simulink is in a weird form. Does anyone know how to get around this. Thanks.

Risposta accettata

Ameer Hamza
Ameer Hamza il 13 Apr 2020
In the Simulink PID block, In the form field, change the form from parallel to ideal and set the value of filter coefficient N to be quite high (say 200). Then parameters P, I, and D can be used from your current transfer function.
  2 Commenti
Uzair Akhtar
Uzair Akhtar il 13 Apr 2020
Thank you. Do you know what impact the filter coefficient N has to the system.
Ameer Hamza
Ameer Hamza il 14 Apr 2020
PID block uses a low-pass filter for D term. The value of N controls the stop-band of the low-pass filter. Higher the value of N, higher is the stop-band frequency. For the low-value of N, the PID block will smooth the derivative of your system. If you have a high value of N, the filter will have no significant effect.

Accedi per commentare.