Simulink vector to scalar stream
5 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I have a fixed-step (1ms) project. I have a block outputting a 7680x1 vector every 1ms. This output feeds a subsytem that does not accept vector input. Only scalar. So its giving a compile error. What can I do?
0 Commenti
Risposte (1)
Ameer Hamza
il 21 Apr 2020
See from workspace block: https://www.mathworks.com/help/releases/R2020a/simulink/slref/fromworkspace.html. Create a matrix with two columns in the MATLAB workspace. The first column is the time value, spaces by 0.001 seconds, and the second column is data. This block will read the data, one value at a time.
5 Commenti
Ameer Hamza
il 21 Apr 2020
The "from workspace" block serialize the vector to give one value at each time interval. You can change the first column of the input matrix to specify whatever time-sample you want.
Vedere anche
Categorie
Scopri di più su Subsystems in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!