How to create/ simulate fault in asynchronous machine in simulink?

2 visualizzazioni (ultimi 30 giorni)
How can I simulate the faults in the asynchronous machine ?ex: broken bar or stator winding.

Risposte (1)

Sabin
Sabin il 30 Gen 2025
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding slot level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point:

Categorie

Scopri di più su Electrical Block Libraries in Help Center e File Exchange

Prodotti

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!