Azzera filtri
Azzera filtri

Running .m and simulink (.slx) file together

7 visualizzazioni (ultimi 30 giorni)
I ran in to trouble while working with NI DAQ (USB 6251). I wanted to integrate everything is simulink and they dont provide block for counter (Can't use DIs). So I used function block with coder.extrensic() function and it works but my counter resets everytime. Following is my code,
function data = functionRead1()
data = zeros(1,1); %Preinitialization
coder.extrinsic('daq','addinput','read','table2array'); %define functions as external
d = daq("ni"); % Add DAQ
ch1 = addinput(d, 'Dev1', 'ctr0', 'Position'); % Add Inputs
data = table2array(read(d)); %reads 1 scan cycle and returns accumulated value
end
So the problem is everytime counter resets and I get wront data read in code. Cant use while loop or if...else logic as it goes in loop or throws error.
I have .m file as well for code which works fine. It there any way I can run .m and .slx together on same machine? Or any other solution is fine.
Thanx in advance.

Risposta accettata

Walter Roberson
Walter Roberson il 11 Ago 2020
Use persistent. Check if the persistent variable is empty and if it is then configure it. Then either way, read from the daq.
Note: consider using OutputFormat 'Matrix' instead of the default table.
  3 Commenti
Rutvik Shete
Rutvik Shete il 11 Ago 2020
Thanx a lot. Works really well. :)