I'm running a Simulink simulation that outputs three scalars. The sinals show as scalars using the size display in Simulink.
However, when I output the values as timeseries into the workspace I get different sizes. Mores specifically, if I'm running n steps the first output has [n,1] size and the other two have a [1,1,n] size.
I assume the difference will lie in the forward propagation of the blocks just before it. For reference these are:
Dot product: leads to a [n,1] sized output
Trig functions: lead to an [1,1,n] sized output.
Any clue about this difference, and if possible, about how to make them homogeneous?

 Risposta accettata

This comes to the aspect that the input signals here are treated as a 2-D scalar (Dimension: [1x1]) at each time step, instead of a 1-D scalar. Simulink treats these two types of scalars as distinct. Consequently, as per the documentation, the logged signals are then 3-D arrays instead of 2-D arrays.

Più risposte (0)