Process raw data using lowpass filter

8 visualizzazioni (ultimi 30 giorni)
nam bui
nam bui il 10 Feb 2021
Commentato: Rahim Nami il 13 Ott 2022
Hi,
I have a excel file with raw data containg 1200 rows and 2 columns named A and B. I'm try to apply a lowpass filter on the signal but looks like its not working, hopefully someone on here may have time to guide me to the right direction.
here is what I did so far:
imported data as a table -> created a script -> inside of the script -> load rawdata.csv
% sampling frequency [Hz]
Fs = 1000;
% sampling period [s]
Ts = 1/Fs;
% time vector [s]
t = 0:Ts:3;
% Signal A
sig_A = rawdata(:,1);
% Signal A
sig_B = rawdata(:,2);
order = 4;
fcut = 8000;
[sig_A,sig_B] = butter(order,fcut/(fs/2),'low');
x = filter(sig_A,sig_B);

Risposta accettata

Alberto Mora
Alberto Mora il 10 Feb 2021
Modificato: Alberto Mora il 10 Feb 2021
You are confusing the filter coefficient with the raw signal.
Try this:
[b,a] = butter(order,fcut/(fs/2),'low');
sig_a_filt = filter(b, a, sig_A );
  5 Commenti
nam bui
nam bui il 10 Feb 2021
this is help, thank you and I'll accep this as anwser for sure
Rahim Nami
Rahim Nami il 13 Ott 2022
Hi everyone
Please, mathematical formula or mathematical model of the codes used. you insert
thank you
r_nami@gmx.com

Accedi per commentare.

Più risposte (0)

Categorie

Scopri di più su Statistics and Linear Algebra in Help Center e File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!