Azzera filtri
Azzera filtri

Current measurement and voltage measurement

11 visualizzazioni (ultimi 30 giorni)
Hitesh Goyal
Hitesh Goyal il 20 Mar 2021
Risposto: Xiangchun il 15 Lug 2022
Hello!
I am working on a battery overcharge protection circuit. I can't understand why I can't current measurement and voltage measurement blocks in the circuit.
Though I can connect voltage sensor and current sensor.
Also, what is the difference betweeen these two blocks.
(Image of the circuit attached for reference)
Thanks!

Risposte (1)

Xiangchun
Xiangchun il 15 Lug 2022
Hi Hitesh,
Voltage sensor and current sensor are Simscape blocks and they work with physical signals, whereas current measurement and voltage measurement blocks are Simulink blockes and they work with Simulink signals.
Voltage sensor and current sensor can be connected to the blue connection lines in the Simscape because these two blocks are Simscape blocks.
For additional information on connecting Simscape diagrams to Simulink sources and scopes, please see the documentation here.
Best wishes,
Xiangchun

Categorie

Scopri di più su Battery Pack Modeling in Help Center e File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by