absolute tolerance of reducepoly

1 visualizzazione (ultimi 30 giorni)
reducepoly has an optional input "tolerance" which is a number in the range [0,1]. Is there a way to specify the absolute tolerance or another way to achieve this?

Risposta accettata

Anmol Dhiman
Anmol Dhiman il 8 Apr 2021
Hi Margaret,
According to the documentation, the only way to specify the absolute tolerence ( maximum reduction in points) is by keeping it 1.
Hope it helps
Anmol
  1 Commento
Margaret Pavlovich
Margaret Pavlovich il 12 Apr 2021
I meant absolute tolerance as opposed to relative tolerance. That is, I wanted to reduce the number of points on the curve while keeping the reduced curve within epsilon of the original. It is not clear what value of epsilon the tolerance parameter in the function corresponds to, though I assume it is something like tolerance*range.
I solved this by implementing Ramer–Douglas–Peucker algorithm on my own.

Accedi per commentare.