Modeling thermal capacity in simscape
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hello,
I'm trying to implement a thermal model for a PMSM motor. But, i can't find an implemented model for the thermal capacity ( unlike the thermal resistance) so i'm trying to implement it using the cutom component on simscape.
My question is : How to implement this equation in the .ssc file ? to get my custom component thermal capacity.
Or, is there any other alternative to model it?
thank you,
0 Commenti
Risposta accettata
David John
il 3 Ago 2021
Please try right-clicking on the PMSM block from the Simscape Electrical library and choose:
Simscape --> Block choice --> Show thermal port
There is already a thermal model builtin to this block.
0 Commenti
Più risposte (0)