How to solve this issue Variable 'X' is not fully defined on some execution paths.

10 visualizzazioni (ultimi 30 giorni)
Dear All,
I have a code into a MATLABFUNCTION block of Simulink that jump out this error message "
Variable 'CONDICIONTRAMO' is not fully defined on some execution paths. Function 'Battery_Control/Function_Cruz_v2' (#25.1881.1895), line 57, column 12: "CONDICIONTRAMO" Launch diagnostic report."
Anyone of you can help me out to find the way to solve this ? Please.
function [SOC_CC, Bat_charge] = BUsage(top, SOC, SOC_Seg, SOCint, W_demand, Power_PV)
if SOC>=SOC_Seg
SOC_CC=0;
Bat_charge=0;
return
else
if SOC>=SOCint
SOC_CC=1;
Bat_charge=0;
end
if SOC<=SOCint
if (top>=8)||(top<=9) && Power_PV>W_demand
CONDICIONTRAMO = 1;
disp('Llano 1 de 8 a 9')
elseif (top>=8)||(top<=9) && Power_PV<W_demand
CONDICIONTRAMO = 2;
disp('"-" Llano 1 de 8 a 9')
elseif (top>=10)||(top<=13) && Power_PV>W_demand
CONDICIONTRAMO = 3;
disp('Punta 1 de 10 a 13')
elseif (top>=10)||(top<=13) && Power_PV<W_demand
CONDICIONTRAMO = 4;
disp('"-"Punta 1 de 10 a 13')
elseif (top>=14)||(top<=17) && Power_PV>W_demand
CONDICIONTRAMO = 5;
disp('Llano 2 de 14 a 17')
elseif (top>=14)||(top<=17) && Power_PV<W_demand
CONDICIONTRAMO = 6;
disp('"-"Llano 2 de 14 a 17')
elseif (top>=18)||(top<=21)&& Power_PV>W_demand
CONDICIONTRAMO = 7;
disp('Punta 2 de 18 a 21')
elseif (top>=18)||(top<=21)&& Power_PV<W_demand
CONDICIONTRAMO = 8;
disp('"-"Punta 2 de 18 a 21')
elseif (top>=22)||(top<=23)&& Power_PV>W_demand
CONDICIONTRAMO = 9;
disp('Llano 3 de 22 a 23:59')
elseif (top>=22)||(top<=23)&& Power_PV<W_demand
CONDICIONTRAMO = 10;
disp('"-"Llano 3 de 22 a 23:59')
elseif (top>=24)||(top<=8) && Power_PV<W_demand
CONDICIONTRAMO =11;
disp('Valle de 24 a 8')
end
switch CONDICIONTRAMO
case 1
SOC_CC=1;
Bat_charge=0;
case 2
SOC_CC=0;
Bat_charge=0;
case 3
SOC_CC=1;
Bat_charge=0;
case 4
SOC_CC=0;
Bat_charge=0;
case 5
SOC_CC=1;
Bat_charge=0;
case 6
SOC_CC=0;
Bat_charge=0;
case 7
SOC_CC=1;
Bat_charge=0;
case 8
SOC_CC=0;
Bat_charge=0;
case 9
SOC_CC=1;
Bat_charge=0;
case 10
SOC_CC=0;
Bat_charge=0;
case 11
SOC_CC=1;
Bat_charge=1;
otherwise
disp('No')
end
end
end
end

Risposta accettata

Jan
Jan il 30 Giu 2021
Modificato: Jan il 30 Giu 2021
Insert a definition of CONDICIONTRAMO = -1 (or NaN, or 12) either on top of the code, before the IF branchs, or in a finaly else branch:
...
elseif (top>=24)||(top<=8) && Power_PV<W_demand
CONDICIONTRAMO =11;
disp('Valle de 24 a 8')
else
CONDICIONTRAMO = 12;
end
But then Bat_charge is not defined in all branchs. Add a default value for this variable also.
By the way, the Switch/Case-Block is hard to read. Maybe this is tougher:
% 1 2 3 4 5 6 7 8 9 10 11 12
SOC_CC_V = [1 0 1 0 1 0 1 0 1 0 1 NaN];
Bat_charge_V = [0 0 0 0 0 0 0 0 0 0 1 NaN];
SOC_CC = SOC_CC_V(CONDICIONTRAMO);
Bat_charge = Bat_charge_V(CONDICIONTRAMO);
  7 Commenti
Jan
Jan il 2 Lug 2021
As far as I understand, this is another problem. If so, please open a new thread to get support.

Accedi per commentare.

Più risposte (0)