How can I resample 3051.7578Hz data in 1000Hz?
5 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Soo Hyun Park
il 12 Lug 2021
Modificato: Soo Hyun Park
il 13 Lug 2021
I have a set of time series sampled at 3051.7578Hz. I want to resample the data in 1000Hz (in millisecond resolution). What would be a good way? It seems that "resample" function only deals with a time series collected in a fixed rate (i.e. take only integers for sampling rate input). Should I design a sort of filter?
0 Commenti
Risposta accettata
Più risposte (1)
Jonas
il 12 Lug 2021
use the interp1() function, it can also deal with non uniformly sampled data
0 Commenti