Why do I receive an error when using the Breaker block with my SimPowerSystems model in Simulink 6.2 (R14SP2)?
    2 visualizzazioni (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
I created a model using the Breaker block in SimPowerSystems 4.0 (R14SP1). When I load this model into R14SP2, I received the following message in the Simulink error dialog:
 Subscript Indices must be either real positive integers or logicals.
Risposta accettata
  MathWorks Support Team
    
 il 27 Giu 2009
        We have verified that there is a bug in SimPowerSystems 4.0.1 (R14SP2) in the way Breaker blocks from earlier versions are handled if the link to the SimPowerSystems library has been disabled. There are two approaches to working around this issue:
1. Right-click on the blocks in question and select Link Options->Restore Link.
2. Use the PSBUPDATE command from the command prompt to restore all disabled library links for SimPowerSystems blocks. An example of the syntax is:
psbupdate my_model
In the above example, "my_model" is the name of your Simulink model.
0 Commenti
Più risposte (0)
Vedere anche
Categorie
				Scopri di più su Switches and Breakers in Help Center e File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!