Why does the runtime API in Simulink output a empty signal at the output of an atomic subsystem in Simulink version 6.4(R2006a)?
2 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I have an atomic subsystem called 'MYSUB' in my simulink model 'MYMODEL' and I execute the following code on the MATLAB command prompt.
rto = get_param('MYMODEL\MYSUB', 'runtimeobject') % gcb is an atomic subsystem
op = rto.OutputPort(1);
mydata=op.data;
The output port data 'mydata' is empty although a valid signal is propagated to the output port.
Risposta accettata
MathWorks Support Team
il 27 Giu 2009
This enhancement has been incorporated in Release 2009a (R2009a). For previous product releases, read below for any possible workarounds:
For previous releases, as a workaround, one can connect another block, e.g. an outport block to the output of the subsystem and use the RunTimeObject of that block.