stateflow 코드 생성
Hi Youngjin, In Stateflow, the “Saturate on integer overflow” option controls how overflow is handled. In this scenario, you c...
4 mesi fa | 0
Unable to change signal name in data inspector
Hi Zbigniew, To modify a signal field name in the Simulation Data Inspector, double-click directly on the signal name and typ...
4 mesi fa | 0
In Online MATLAB Simscape models will not run and give error
Hi Igor, Sometimes testing of specific features can be turned off. You can try enabling them with a toggle using the lic...
4 mesi fa | 0
Unable to run the Simulink model in "Rapid Accelerator mode"
Hi, I encountered a similar issue when I was trying to run a Simulink model in accelerated mode. In my case, the error was caus...
4 mesi fa | 0
Stateflow webview - monitoring enum value
Hi Brandon, Currently, the HTML Web View does not directly display the enum integer value of a Stateflow leaf state in the Pr...
4 mesi fa | 0
TLC function generation hook
Hi Eamon, Yes, this is possible without post-processing but there’s no single TLC function that will automatically instrument ...
5 mesi fa | 0
How to Transfer MATLAB Simulink-Generated CCS Project with Dependencies?
Hi Haadia, To ensure your CCS project is portable and does not require MATLAB, you can use MATLAB’s "packNGo" utility. Here is ...
5 mesi fa | 0
Giving additional resource(.so file) to an s-function and generate FMU
Hi Mayur, If your S-function depends on a .so file and you're trying to generate a portable FMU that works across different...
5 mesi fa | 0
Linearization in GFM-based power system
Hi Lucas, Based on my experience with similar setups, I recommend using the Linearization Manager (Model Linearizer) in...
5 mesi fa | 0
Help with BACK EMF measurement
Hi Virag, It looks like the oscilloscope screenshot you mentioned didn’t come through with your message. If you’re able...
5 mesi fa | 0