creepydog
Followers: 0 Following: 0
Statistiche
RANK
10.504
of 289.749
REPUTAZIONE
4
CONTRIBUTI
6 Domande
2 Risposte
ACCETTAZIONE DELLE RISPOSTE
33.33%
VOTI RICEVUTI
4
CONTRIBUTI
0 Post
CONTRIBUTI
0 Pubblico Canali
VALUTAZIONE MEDIA
CONTRIBUTI
0 Punti principali
NUMERO MEDIO DI LIKE
Feeds
Domanda
Enabled Subsystem does not reliably disable
The Simulink model shown in the screenshot does not behave as I expect, and I would like to understand the reason. All blocks...
9 giorni fa | 0 risposte | 1
0
risposteRisolto
Remove the polynomials that have positive real elements of their roots.
The characteristic equation for a dynamic system is a polynomial whose roots indicate its behavior. If any of the roots of the p...
quasi 2 anni fa
Risolto
Summing digits
Given n, find the sum of the digits that make up 2^n. Example: Input n = 7 Output b = 11 since 2^7 = 128, and 1 + ...
quasi 2 anni fa
Risolto
Finding Perfect Squares
Given a vector of numbers, return true if one of the numbers is a square of one of the numbers. Otherwise return false. Example...
quasi 2 anni fa
Risolto
Interpolator
You have a two vectors, a and b. They are monotonic and the same length. Given a value, va, where va is between a(1) and a(end...
quasi 2 anni fa
Risolto
Times 2 - START HERE
Try out this test problem first. Given the variable x as your input, multiply it by two and put the result in y. Examples:...
quasi 2 anni fa
Domanda
Rank of symbolic matrix is wrong (but too small, not too large)
I get a wrong result using the sym/rank command. I'm aware of the limitations of this command as it does not simplify expression...
oltre 2 anni fa | 1 risposta | 1
1
rispostaDomanda
Simulation runs fine despite error (index out of bounds)
Hello. Summary For my simple model, Simulink (R2020b) throws an error during Model Update, but afterwards allows me to simulat...
circa 3 anni fa | 1 risposta | 1
1
rispostaNumber of necessary time steps to handle a Zero-Crossing?
First of all: Thank you for your efforts! Your guesses are similar to my guesses. ;-) I've been aware of the fact that my minim...
quasi 4 anni fa | 0
Domanda
Number of necessary time steps to handle a Zero-Crossing?
Over the years I have observed that Simulink usually uses 3 time steps to handle a zero-crossing, but in some cases it uses only...
quasi 4 anni fa | 2 risposte | 0
2
risposteWhat do TzL & TzR mean in Simulink Debugger ?
I've seen these when debugging zero-crossings. So "z" might mean "zero-crossing", "L" and "R" might be "left" (before) and "righ...
quasi 4 anni fa | 0
Domanda
Integrator State Port: Why is its use restricted?
Hello. I'd like to know why the use of the Integrator Block's State Port is restricted (and I have some more questions, see bel...
quasi 4 anni fa | 2 risposte | 1
2
risposteDomanda
How can I get the figure handle of a Scope window programmatically, given only the Scope block's full path name?
I've got the full path name of a Scope *block* as it is returned by find_system(...), e.g. 'myModel/Scope1'. In order to mani...
quasi 7 anni fa | 2 risposte | 0