Community Profile

photo

Andy Bartlett

Last seen: 1 giorno fa Attivo dal 2015

Statistics

All
  • 24 Month Streak
  • Knowledgeable Level 4
  • Personal Best Downloads Level 1
  • GitHub Submissions Level 1
  • 5-Star Galaxy Level 1
  • First Submission
  • Revival Level 2
  • First Answer

Visualizza badge

Content Feed

Visto da

Risposto
help required for fixed point conversion
The number 395 is how many times that block in the model overflowed during the previous simulation. Suppose the element was a da...

2 giorni fa | 0

Risposto
help required for fixed point conversion
Hi Gary, That portion of your model will involve 4 data types. Digital measurement of output signal from analog plant Set poi...

3 giorni fa | 0

Risposto
Overflows when I use Fixed-Point Tool
Two Kinds of Overflows Fixed-Point Tool presents two types of overflows, Actual and Potential. Actual Overflows Actual overfl...

4 giorni fa | 0

| accettato

Risposto
Problem with Simulink.NumericType after AUTOSAR-XML (ARXML) import
To simulate the model with the fixed-point data types and see bit-true behavior will require a Fixed-Point Designer license. Ho...

9 giorni fa | 0

Risposto
Can we replace parameter value with parameter name while generating C code from model?
Please see the documentation Macro Definitions (#define) - MATLAB & Simulink (mathworks.com)

10 giorni fa | 0

Risposto
Am I missing something, or is the Tip wrong?
Hi, The advise is generally correct. Turning off Integer Saturation and allowing the math to wrap modulo 2^N will lead to lea...

12 giorni fa | 1

Risposto
Why is my Simulink data type randomly changing?
Yes, this is most likely due to attribute propagation. You likely have an underspecified "chicken and egg loop" in your model. T...

18 giorni fa | 1

| accettato

Risposto
What is the efficient code?
Simple Ansewer: Use shift approach unless multiplicative constant is really big In my experience, the multiply by constant foll...

18 giorni fa | 0

Risposto
Method of Real number multiplication operation
Quick Answer: Shifts are Multiply or Divide by a Power of Two Shift left of M bits is equivalent to multiplication by 2^M wh...

26 giorni fa | 0

| accettato

Risposto
Trouble using fixed point type conversion in Simulink
Check rounding and overflow handling mode By default, the Data Type Conversion block rounds to Floor and Wraps overflows. In c...

circa un mese fa | 0

| accettato

Risposto
What is the "net slope"
Net slope is used in fixed-point operations to achieve agreement of scaling. The slopes of all the variables involved in an oper...

circa un mese fa | 0

| accettato

Risposto
Simulink model converts floating-point numbers to fixed-point numbers
Suggestion consider using modByConstant Since the "denominator" of your modulos are constants, you my wish to use the modByCons...

circa un mese fa | 0

Risposto
Simulink model converts floating-point numbers to fixed-point numbers
By default zeros() gives double Your output is double because of how it is initialized with the zeros() function n = 3; m = 4...

circa un mese fa | 0

| accettato

Risposto
Data type conversion changes the value of the signal
Why cast to single has large quantization error. The cast from fixed-point to single will use single precision for constants an...

circa 2 mesi fa | 0

| accettato

Risposto
Data type conversion changes the value of the signal
Brief answer The original value 0.1 is between two representable values (0.099609375 and 0.1005859375) of the type being quanti...

circa 2 mesi fa | 0

Risposto
Time delay threshold for constant output
I suggest you start by writing down on paper the equations or pseudo code that you think will solve the requirements of your pro...

2 mesi fa | 0

Risposto
Error in Divide Block - System Generator
The System Generator is a Simulink add-on product developed by AMD (Xilinx). The data types mentioned in the error message, Fix...

2 mesi fa | 0

| accettato

Risposto
Remainder of a division operation in System Generator
Consider restructuring your design to work in units of revolutions instead of in degrees. In that case you only need to perform ...

2 mesi fa | 0

| accettato

Risposto
Simulink Moving Average block not averaging according to the window length specified
Hi Shani, Please create a simplified model that exercises the Moving Average Block in isolation. Create a test input sequence...

3 mesi fa | 0

Risposto
Floating-Point to Fixed-Point Conversion of IIR Filters
Hi, Examples often depend on supporting files. To successfully run these examples, all the files needed by the example need to ...

3 mesi fa | 0

Risposto
FAQ: Why does a value look more precise when displayed in MATLAB or Simulink than in the generated code?
Textual Representation is Often an Approximation The textual representation of values displayed in MATLAB and Simulink is ofte...

4 mesi fa | 0

| accettato

Risposto
Which block's fixed format will be optimized firstly in Fixed-Point tool?
Hi Lin, The optimization proceedure used by Fixed-Point Tool Optimization Conversion workflow is not designed to be determinist...

4 mesi fa | 0

| accettato

Risposto
Simulink ADD block keeps returning 255
My guess is that Sum block's output data type is uint8, and the block is configured to wrap on integer overflows. So the output...

4 mesi fa | 0

Risposto
n-D Lookup Table dimension error
There are two issues. For simplicity, I'll assume the block is configured to do linear interpolation and extrapolation. First,...

4 mesi fa | 1

| accettato

Risposto
How to read and write to an upper half or a specific bit from a decimal number in Simulink?
Bitwise AND, OR, XOR, NOT (aka complement), shift, ... are the ways commonly used to set, clear, or otherwise manipulate bits ...

4 mesi fa | 1

| accettato

Risposto
Interfacing hardware components with fixed bit width in Simulink/HDL Coder
Reinterpret Scaling Cast A technique to achieve goals like you described is to use a "Reinterpret Scaling Cast". The key idea o...

4 mesi fa | 0

| accettato

Risposto
define a counter which will starts counting from zero automatically when the count reaches to 10
In a Simulink model, click on the canvas and type "counter" you'll see a list of blocks one of these is called Counter Limited...

5 mesi fa | 0

Risposto
fiaccel set fi numeric type based on input
When using MATLAB Code with MATLAB Coder, MATLAB Function Block, or fiaccel, the numeric type of a variable is not allowed to ch...

5 mesi fa | 1

| accettato

Risposto
INHERIT VIA BACKPROPAGATION MEANS
Inherit via Back Propagation The purpose of the setting Inherit via Back Propagation is for a block have its output data type ...

5 mesi fa | 0

| accettato

Risposto
Changing significant digits of constant block
The constant block is showing the text that is entered for the parameter, and is not showing the evaluated numeric value. You do...

5 mesi fa | 2

| accettato

Carica altro