Having problems with solver settings and step size in simscape electrical
Hello, I problems with undertanding solver settings and step size in simscape electrical, I attached the model to make it easie...

oltre un anno fa | 1 risposta | 0

1

risposta

Domanda


help understand the step size of the electrical engine dyno example
Hello I have a question the the folowing Electric Engine Dyno example ( https://de.mathworks.com/help/sps/ug/electric-engine-dy...

oltre un anno fa | 1 risposta | 0

1

risposta

Domanda


difference between "Control sample time " and "Fundamental sample time " for FOC
Hello while Implementing a drive with a Field-oriented-Control i couldn't get the difference between "Control sample time " an...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Iterpolation shows wrong results
Hello I have a major problem with my results that I can't seem to find its reason My model beginns with an electrical loads ...

quasi 2 anni fa | 2 risposte | 0

2

risposte

Domanda


induction motor response not satisfying
Hello as mentionned the response of the induction motor, its speed, isn't fully as it should be. it's not wrong bet needs adjus...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


How to measure the frequency of a 3 phase generator in simscape electrical
Hello I would like to measure the freqeuncy of a 3 phase signal generated by a 3 phase generator in simscape electrical? I did...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


unbalanced load on a synchronous generator
Hello, I would like to apply an asymetrical load to a synchronous generator. The original model has 3ph dynamic AC load as sho...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Tuning exciter parameters for a synchronous generator
Hello, I used the following exciter block for synchronous generator for the parameters I used those of an example in simsca...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Implement a Motor drive with constant speed
Hello, for a project I need to implement an induction motor which operats under variable torque while keeping its speed at 1500...

quasi 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Add a Simscape Multibody model to a Simscape Electrical model
Hello I just found out that you can use a CAD file to generate a Simscape Multibody model, so I wanted to ask if it's possible ...

circa 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Parameters of the squirrel cage motor
Hello I need a model of the squirrel cage induction machine for 250kW, 400V and 50Hz but the available models go only up to 160...

circa 2 anni fa | 1 risposta | 1

1

risposta

Domanda


does the rotational port S recognize the load flow?
Hello, for a projct I need to connect an asynchronous motor with a synchronous generator, which will supplement an island grid....

circa 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Understand the inputs of the asynchronous machine
Hello I'm getting started with simscape specialized power systems and I don't get the input for the asynchronous machine in mot...

circa 2 anni fa | 1 risposta | 0

1

risposta

Domanda


Mechanical rotational port of Induction Motor from the specialized power system library
Hello, I want to build a rotary frequency converter using an induction motor and a synchronous generator, connected to each oth...

circa 2 anni fa | 1 risposta | 0

1

risposta