Domanda
Having problems with solver settings and step size in simscape electrical
Hello, I problems with undertanding solver settings and step size in simscape electrical, I attached the model to make it easie...
8 mesi fa | 1 risposta | 0
1
rispostaDomanda
help understand the step size of the electrical engine dyno example
Hello I have a question the the folowing Electric Engine Dyno example ( https://de.mathworks.com/help/sps/ug/electric-engine-dy...
8 mesi fa | 1 risposta | 0
1
rispostaDomanda
difference between "Control sample time " and "Fundamental sample time " for FOC
Hello while Implementing a drive with a Field-oriented-Control i couldn't get the difference between "Control sample time " an...
8 mesi fa | 1 risposta | 0
1
rispostaDomanda
Iterpolation shows wrong results
Hello I have a major problem with my results that I can't seem to find its reason My model beginns with an electrical loads ...
8 mesi fa | 0 risposte | 0
0
risposteDomanda
induction motor response not satisfying
Hello as mentionned the response of the induction motor, its speed, isn't fully as it should be. it's not wrong bet needs adjus...
8 mesi fa | 1 risposta | 0
1
rispostaDomanda
How to measure the frequency of a 3 phase generator in simscape electrical
Hello I would like to measure the freqeuncy of a 3 phase signal generated by a 3 phase generator in simscape electrical? I did...
8 mesi fa | 1 risposta | 0
1
rispostaDomanda
unbalanced load on a synchronous generator
Hello, I would like to apply an asymetrical load to a synchronous generator. The original model has 3ph dynamic AC load as sho...
10 mesi fa | 1 risposta | 0
1
rispostaDomanda
Tuning exciter parameters for a synchronous generator
Hello, I used the following exciter block for synchronous generator for the parameters I used those of an example in simsca...
10 mesi fa | 1 risposta | 0
1
rispostaDomanda
Implement a Motor drive with constant speed
Hello, for a project I need to implement an induction motor which operats under variable torque while keeping its speed at 1500...
10 mesi fa | 1 risposta | 0
1
rispostaDomanda
Add a Simscape Multibody model to a Simscape Electrical model
Hello I just found out that you can use a CAD file to generate a Simscape Multibody model, so I wanted to ask if it's possible ...
11 mesi fa | 1 risposta | 0
1
rispostaDomanda
Parameters of the squirrel cage motor
Hello I need a model of the squirrel cage induction machine for 250kW, 400V and 50Hz but the available models go only up to 160...
12 mesi fa | 1 risposta | 1
1
rispostaDomanda
does the rotational port S recognize the load flow?
Hello, for a projct I need to connect an asynchronous motor with a synchronous generator, which will supplement an island grid....
12 mesi fa | 1 risposta | 0
1
rispostaDomanda
Understand the inputs of the asynchronous machine
Hello I'm getting started with simscape specialized power systems and I don't get the input for the asynchronous machine in mot...
circa un anno fa | 1 risposta | 0
1
rispostaDomanda
Mechanical rotational port of Induction Motor from the specialized power system library
Hello, I want to build a rotary frequency converter using an induction motor and a synchronous generator, connected to each oth...
circa un anno fa | 1 risposta | 0