Check Output data type of operation blocks
Check ID:
mathworks.jmaab_v6.jc_0651
Guideline: jc_0651: Implementing a type conversion
Description
Checks for numerical operation blocks in a model that directly specify the Output data type parameter.
Exception: This check will not analyze the inport blocks of Simulink® functions. However, it analyzes the following blocks:
Constant
Data Type Conversion
Bus Creator
Enable Port
Data Store Memory
Compare To Constant
InportShadow
This check requires a Simulink Check™ license.
Check Parameterization
This check does not include sub-checks because the MAB modeling guideline provides only one sub ID.
For reference, the MAB guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
NA-MAAB — No recommendations
JMAAB — a
Results and Recommended Actions
Condition | Recommended Action |
---|---|
One or more numerical operation blocks directly specify the Output data type parameter. | Instead of directly specifying the Output data type parameter in numerical operation blocks, use the Data Type Conversion block to change the data type of a block output signal. |
Capabilities and Limitations
Runs on library models.
Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to
graphical
.Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to
on
.Allows exclusions of blocks or charts.