Simulink Switch Outputs wrong data format

3 visualizzazioni (ultimi 30 giorni)
Hi everyone.
I am currently experiencing problems with the switch block.
I havebuild a basic edge detector:
My Problem now is, that the output of out.TDCValid is a Nx1 Array, but out.TDCValid1 outputs 1x1xN instead the expected Nx1. I cannot figure out why this is. Any Ideas from your side?

Risposta accettata

Fangjun Jiang
Fangjun Jiang il 24 Set 2021
check the size/dimension of the Constant zero block, the "TriggerOUT" Outport block and the Switch block itself. Specify it as [1], not [1 1].
If nothing else, run squeeze(out.TDCValid1)