How to collect last bits of data from background acquisition
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
function trial
s = daq.createSession('ni');
addAnalogInputChannel(s,'Dev1', 'ai0', 'Voltage');
% addDigitalChannel(s,'Dev1','port0/line11','InputOnly');
s.IsContinuous = true;
s.Rate = 100;
s.NotifyWhenDataAvailableExceeds = 100;
% s.DurationInSeconds = 10;
lh = addlistener(s,'DataAvailable', @plotData);
tic;
startBackground(s);
pause(5.2);
stop(s);
toc;
end
function plotData(src,event)
fprintf('Length = %d\n',size(event.Data,1));
end
Im trying to run the above code in R2014a with the session interface. While I am able to get access to the first five data chunks, the last chunk with ~20 data points is not accessible. Any idea why?
stop(s); stops the session and all associated hardware operations in progress. If your operation has acquired data and the DataAvailable event has not yet fired, the stop command will fire the event and deliver the data acquired up to that point.
4 Commenti
Geoff Hayes
il 22 Ago 2014
Modificato: Geoff Hayes
il 22 Ago 2014
That is surprising/disappointing especially given the description on how the stop function works...
Risposte (0)
Vedere anche
Categorie
Scopri di più su National Instruments Frame Grabbers in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!