How can I set up the lookup table for a 2-way directional valve?

2 visualizzazioni (ultimi 30 giorni)
I need help with why I am getting this error "Dimensions of arrays being concatenated are not consistent. "
I am trying to model a 2-Way Driectional Valve using lookup tables.
  4 Commenti
Voss
Voss il 14 Apr 2022
No idea, sorry. Apparently that's some stuff from Simscape, which I've never used.

Accedi per commentare.

Risposte (1)

Yifeng Tang
Yifeng Tang il 24 Giu 2022
Regarding the error message in you comment:
  • ['Trial/2-Way Directional Valve (IL)']: Size of Volumetric flow rate table, q(s,dp) must be equal to length of Spool travel vector, s by length of Pressure drop vector, dp. In fluids.isothermal_liquid.valves_orifices.directional_control_valves.directional_valve_2_way
It's complaining about size(q) is not the save as [length(s),length(dp)]. q is what you have put in the volumetric flow rate table, and s is the spool travel vector, and dp is the pressure drop vector. The dimensions have to be right, or Simscape doesn't know how to do the look up.