How to filter the noise out from the ECG signal

38 visualizzazioni (ultimi 30 giorni)
YanBo Liu
YanBo Liu il 11 Mag 2022
Risposto: Ganesh il 18 Lug 2023
The original ECG signal looks like this, the sampling frequency is 360Hz.
I try to design a FIR filter to filter the noise out so that i can get a clear view of PQRST complex of the heart beat. I plot this signal in the frequency domain and it looks like this:
So, how should I fiind the frequency where the noise locates?
  4 Commenti
Jonas
Jonas il 11 Mag 2022
i suggest you play around using the signal analyzer app.
https://de.mathworks.com/help/signal/ug/using-signal-analyzer-app.html
tomorrow i will have a closer look!
Star Strider
Star Strider il 11 Mag 2022
There is obvious 60 Hz line noise. Use a bandstop filter with a very narrow stopband to eliminate it.
Beyond that, it appears to represent normal sinus rhythm with left ventricular hypertophy with non-specific ST-T changes and one notable PVC. If this is a Lead II EKG, the origin of the PVC appears to be near the apex. There are Q-waves, however without a specific voltage calibration, it is difficult to interpret their significance.

Accedi per commentare.

Risposte (3)

M.B
M.B il 12 Mag 2022
Modificato: M.B il 12 Mag 2022
I would also recommend a zero-phase filter using filtfilt function to avoid the introduction of phase lag after filtering the signal.

Ganesh
Ganesh il 6 Lug 2023
mat lab code

Ganesh
Ganesh il 18 Lug 2023
Code for that

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by