Azzera filtri
Azzera filtri

bode magnitude producing different plots for the same transfer function

1 visualizzazione (ultimi 30 giorni)
I have transfer function and have manually extracted the magnitude and plotted it. When I used the bodemag function however, the plot looks very different. Im confused as to which one is correct and why they are coming out differently, as I havent applied any unit conversions. For my manual extraction, I have used the following and its produced the plot underneath.
[mag phase] = bode(tf);
Mag = transpose(squeeze(mag));
However, when I use the bodemag(tf) function, I get this:
I dont understand why these reuslts are so different or which one is correct and am looking for some claririfcation.

Risposta accettata

Star Strider
Star Strider il 25 Set 2022
The upper plot is plotted with a linear magnitude and the lower one is plotted with the magnitude in decibels.
  2 Commenti
Paul
Paul il 25 Set 2022
Also, the upper plot x-axis is linear and the lower is log scale. And they don't cover the same max and min values.
Star Strider
Star Strider il 25 Set 2022
Noted. I didn’t catch the frequency axis difference. I was concentrating on the magnitude axis.

Accedi per commentare.

Più risposte (0)