How to implement this c-code: if(Flag == 1) {Flag = 0;} ?

10 visualizzazioni (ultimi 30 giorni)
Charles Wang
Charles Wang il 14 Ott 2011
I used a signal (this is what I needed) for Flag at an input port of stateflow, but Flag is not recognized inside the stateflow. If I add an input data in the stateflow, it will not be allowed to change the value (through a transit with a statement {Flag=0;} inside the stateflow).
Please help. Thanks!

Risposte (1)

Fangjun Jiang
Fangjun Jiang il 14 Ott 2011
This is one of the difference between C and Simulink. In C, you can re-use the variable name. In Simulink, the signal name represents the data flow. You can't re-use the signal name. You have to declare an output for the Stateflow and then assign value accordingly.
  12 Commenti
Fangjun Jiang
Fangjun Jiang il 1 Nov 2011
You are right. Port name is used to identify the port block. The generated code will not necessarily use port name for variable name.
Manjunath Bhimalli
Manjunath Bhimalli il 14 Gen 2019
Try with connecting Unit Delay(1/z) block and take the feedback.