Simulink.B​lockDiagra​m.arrangeS​ystem does not work inside library

6 visualizzazioni (ultimi 30 giorni)
Hello,
I'm using the command:
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true');
to sort and rearrange the blocks inside a masked subsystem. This worked fine until I converted this subsystem into a library block.
Now this command does nothing and the internal structure remains cluttered and unreadabel. Because this blocks heavily modifies itself, I can't establish a pleasant alignment beforehand.
Is there any way to get this working?
  4 Commenti
Fangjun Jiang
Fangjun Jiang il 30 Nov 2022
Sorry, to be acurate, for the library block, I shall refer it as "is the LinkStatus inactive".

Accedi per commentare.

Risposte (1)

Fangjun Jiang
Fangjun Jiang il 30 Nov 2022
I've tried it. You need to disable the library link first.
set_param(gcb,'LinkStatus','inactive')
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true')
  2 Commenti
Manuel K
Manuel K il 1 Dic 2022
Although that's working, I don't want to keep the 'LinkStatus' in the 'inactive' state.
(Restoring it isn't possible because the local instance has different blocks inside, which will get deleted.)
Manuel K
Manuel K il 1 Dic 2022
Modificato: Manuel K il 1 Dic 2022
Since the command only works the first time after placing the library-block (as mentioned in my comment above), my workaround is the following:
Everytime I need to change / update a setting inside the mask of the librry-block, I place a new instance and delete the old one.

Accedi per commentare.

Categorie

Scopri di più su Simulink Functions in Help Center e File Exchange

Prodotti


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by