Simulink - 'MaskPortRotation' is read-only?
17 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I try create a mask for a subsystem including input and output ports but saving gives an error "SubSystem block (mask) parameter 'MaskPortRotate' is read-only? What does it mean and how to proceed? What should I do to be able to save the mask?
2 Commenti
Risposte (2)
Fangjun Jiang
il 25 Gen 2023
If it is read-only, then leave it alone. Don't try to set it.
2 Commenti
Fangjun Jiang
il 30 Gen 2023
Modificato: Fangjun Jiang
il 30 Gen 2023
Can you provide a simplified example model to show the problem?
Or at your Mask Editor dialog, click the "Icon" tab, set "Port Rotation" to "Default".
Jonathan Agg
il 22 Feb 2023
If it occurs again, as a workaround, can you copy the contents of your subsystem into a new subsystem, make a mask on that subsystem, and then replace the original subsystem with the new one? In 22a, the development team are aware of an issue with making masks on subsystems with flexible port placement (subsystems where you have dragged one of the ports around the subsystem boundary to move them), which has been resolved in later releases.