Azzera filtri
Azzera filtri

Simulink - 'MaskPortRotation' is read-only?

17 visualizzazioni (ultimi 30 giorni)
Tommi Meriläinen
Tommi Meriläinen il 24 Gen 2023
Risposto: Jonathan Agg il 22 Feb 2023
I try create a mask for a subsystem including input and output ports but saving gives an error "SubSystem block (mask) parameter 'MaskPortRotate' is read-only? What does it mean and how to proceed? What should I do to be able to save the mask?
  2 Commenti
Jonathan Agg
Jonathan Agg il 20 Feb 2023
Hi Tommi,
Which release do you see this error in?
Jonathan
Fangjun Jiang
Fangjun Jiang il 20 Feb 2023
R2022a. It is noted.

Accedi per commentare.

Risposte (2)

Fangjun Jiang
Fangjun Jiang il 25 Gen 2023
If it is read-only, then leave it alone. Don't try to set it.
  2 Commenti
Tommi Meriläinen
Tommi Meriläinen il 30 Gen 2023
Thanks, but I cannot save the mask I created because of the error. What should I do to be able to save the mask?
Fangjun Jiang
Fangjun Jiang il 30 Gen 2023
Modificato: Fangjun Jiang il 30 Gen 2023
Can you provide a simplified example model to show the problem?
Or at your Mask Editor dialog, click the "Icon" tab, set "Port Rotation" to "Default".

Accedi per commentare.


Jonathan Agg
Jonathan Agg il 22 Feb 2023
If it occurs again, as a workaround, can you copy the contents of your subsystem into a new subsystem, make a mask on that subsystem, and then replace the original subsystem with the new one? In 22a, the development team are aware of an issue with making masks on subsystems with flexible port placement (subsystems where you have dragged one of the ports around the subsystem boundary to move them), which has been resolved in later releases.