How to converge 3 phases of simulink voltage onto a simscape VI measurement which accepts 1 port

2 visualizzazioni (ultimi 30 giorni)
As mentioned, I'm wanting working between simulink and simscape libraries. My voltage source block outputs 3 phases of voltage, although the measurement block that I need accepts a single connection with 3 signals. Notsure how to get around this as cant use a mux. Any help would be much appreciated!

Risposte (3)

Joel Van Sickel
Joel Van Sickel il 8 Feb 2023
This block lets you switch between one line representations of 3 phase wires: https://www.mathworks.com/help/sps/ref/phasesplitter.html;jsessionid=12d81ff0f3faaf382533c296ec45

Mohamad Nazir
Mohamad Nazir il 8 Feb 2023
All you have to do is right click on the current & voltage sensor, choose Simscape > Modeling option > expanded three-phase ports, as you can see in the attached screenshot

Sabin
Sabin il 8 Feb 2023
You can directly use a Controlled Voltage Source (Three-Phase) in Simscape Electrical. Assuming that the Subsystem you have is using blocks from the Simscape technology you can directly connect it to the measurement sensor by changing the 'Modeling option' dropdown in the Current and Voltage Sensor (Three-Phase) to 'Expanded three-phase ports'. I hope this helps.

Community

Più risposte nel  Power Electronics Control

Categorie

Scopri di più su Electrical Sensors in Help Center e File Exchange

Prodotti


Release

R2021b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by