Azzera filtri
Azzera filtri

Toggle between temperature units for unit conversion

1 visualizzazione (ultimi 30 giorni)
Hi,
I am trying to make a simple temeprature unit conversion app in MATLAB app maker with a dropdown menu to toggle between temperature units: C, F, and K. I used switch case function to convert degree c to F or K; however, when I want to return back to c or toggle between the units the program gives wrong values. Please help me complete the code to be able to toggle between temperature units. Thanks
function DropDownValueChanged(app, event)
Value=app.TemperatureEditField.Value
switch app.DropDown.Value
case 'C'
app.TemperatureEditField.Value=Value;
case 'F'
app.TemperatureEditField.Value=Value*1.8+32;
case 'K'
app.TemperatureEditField.Value=Value+273.15;
end
end
  1 Commento
Fangjun Jiang
Fangjun Jiang il 14 Feb 2023
Of course it has issues. If you continue selecting "K", the program flow will continu adding 273.15 to the current value. You need to add something to recognize the current unit.

Accedi per commentare.

Risposta accettata

Voss
Voss il 17 Feb 2023
You need to take into account what the old unit was before it was changed. Fortunately, the ValueChangedFcn of a uidropdown provides an event structure which contains that information. See the attached app.
  2 Commenti
Jon
Jon il 17 Feb 2023
Very nice!
Gives the OP what he wanted with an interface with just one box. Good to know that the event structure returns the previous value.
Fazlollah
Fazlollah il 23 Feb 2023
Modificato: Fazlollah il 23 Feb 2023
Thank you Voss, this is working great.
With this conversion, I have another question. Assume I have an equation for density of water as a function of temperature in degree C. For example,
Rho_H2O=999.6+2.0438e-1*Tc-6.174e-2*Tc^1.5
If my temperature input is in F, then how can I tell the program to put the temperatuer in degree C into the density equation? Can you help me with this one too?

Accedi per commentare.

Più risposte (1)

Jon
Jon il 14 Feb 2023
Modificato: Jon il 14 Feb 2023
I think this does what you want.
I have fixed a few errors in your original code, I think you were confused about the value of the drop down selection and the value of the temperature, which was in the edit field.
Also I added another edit field for the resulting output in the new units. Otherwise, as mentioned by @Fangjun Jiang, with repeated operation the value stored in the original edit field no longer has units of C, so the conversion which you have which convert from C to F or K would no longer be correct. Easier to keep the original value as is and then just output to a different edit field.
  11 Commenti
Fazlollah
Fazlollah il 23 Feb 2023
Modificato: Fazlollah il 23 Feb 2023
Thank you Jon for the answer, yours also works perfectly. However, Voss answer is easier for me to understand.
With this conversion, I have another question. Assume I have an equation for density of water as a function of temperature in degree C. For example,
Rho_H2O=999.6+2.0438e-1*Tc-6.174e-2*Tc^1.5
If my temperature input is in F, then how can I tell the program to put the temperatuer in degree C into the density equation? Can you help me with this one too?
Image Analyst
Image Analyst il 23 Feb 2023
Not sure what you mean. Isn't it the obvious:
Tc = (Tf - 32) * 5/9;
Rho_H2O = 999.6 + 2.0438e-1 * Tc - 6.174e-2 * Tc ^ 1.5

Accedi per commentare.

Categorie

Scopri di più su Function Creation in Help Center e File Exchange

Prodotti


Release

R2020a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by